+7 (812) 200-96-95

DT20 - DT20-P130B1025 - 1029922

Производитель:  Sick
Артикул: sick143655
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measurement range:100 mm ... 250 mm, 18 % ... 90 % remission 1)
Resolution 2):1 mm / 2 mm
Repeatability 3):± 1.5 mm / ± 3 mm
Response time 4):10 ms / 15 ms
Light source:LED, infrared
Typ. light spot size (distance):15 mm x 15 mm (at 1 m)
Additional function:Customer specific scaled measuring range, Plug Play, Switching output to monitor the measuring range
Accuracy:± 4 mm 5) 6)
Laser service life (MTTF at 25 °C):100,000 h
Output time:1 ms
footnote1) ?On 6 % remission the maximal measurable distance is 820 mm 2) 4) Depending on measurement range: 90 ... 600 mm / > 600 mm. 3) 18 % ... 90 % remission 5) 6 % ... 90 % remission 6) ± 4 mm u to 600 mm; ? ±7 mm for distances larger < 600 mm; refer to accuracy diagram

Interfaces

Output type 1):1 x PNP (100 mA)
Analog output:1 x 4 mA ... 20 mA (? 300 ?)
footnote1) PNP: HIGH = VS - (< 2 V) / LOW = 0 V

Mechanics/electronics

Connection type:Male connector, M12, 5-pin
Supply voltage Vs 1):DC 10 V ... 30 V
Power consumption 2):? 1.5 W
Warm-up time:? 30 min
Indication:2 x LED
Weight:135 g
Housing material:Metal housing with PMMA lens
Initialization time:? 250 ms
Ripple:? 5 Vpp 3)
footnote1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A 2) Without load 3) May not fall short of or exceed VS tolerances

Ambient data

Enclosure rating:IP 65
Protection class:II
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +75 °C
Temperature drift:0.25 mm/K
Vibration resistance:EN 60068-2-6 / EN 60068-2-64
Shock resistance:EN 60068-2-27