+7 (812) 200-96-95

Dx50, DT50 Hi - DT50-N2113 - 1047398

Производитель:  Sick
Артикул: sick147414
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measurement range:200 mm ... 20,000 mm, 90 % remision 200 mm ... 5,000 mm, 6 % remission 200 mm ... 8,500 mm, 18 % remission
Resolution:1 mm
Repeatability 1) 2) 3):3 mm / 2 mm / 1 mm
Accuracy 4):± 7 mm
Response time 5) 6):15 ms / 30 ms / 80 ms
Light source:Laser, red
Typ. light spot size (distance):15 mm x 15 mm (10 m)
Additional function:Switch-off display Set moving average fast/medium/slow Set hysteresis Switching mode: distance to object (DtO) Lock user interface Reset to factory default Teach-in, scaling and inversion of analog output Teach-in, scaling and inversion of switching output Multifunctional input: laser off / external teach / deactivated
Laser class:2 (EN 60825-1) 7)
Laser service life (MTTF at 25 °C):100,000 h
Output time 8):? 2 ms
footnote1) Equivalent to 1 ? 2) 6 % ... 90 % remission 3) 5) Dependent on the set average: fast/medium/slow 4) 90 % remision 6) Lateral entry of object into measuring range 7) Wavelength: 658 nm; max. output: 180 mW; pulse duration: 5 ns; pulse repetition rate: 1/200 8) Continuous change of distance in measuring range

Interfaces

Analog output:1 x 4 mA ... 20 mA (? 300 ?)
Resolution analog output:16 bit
Output type 1) 2):1 x NPN (100 mA)
Hysteresis:10 mm ... 1,000 mm
Multifunctional input (MF) 3) 4):1 x
footnote1) Output Q short-circuit protected 2) NPN: HIGH = < 2.5 V / LOW = VS 3) Response time ? 15ms 4) NPN: HIGH = ? 2.5 V / LOW = VS

Mechanics/electronics

Supply voltage Vs 1):DC 10 V ... 30 V
Ripple 2):? 5 Vpp
Power consumption 3):? 2.1 W
Initialization time:? 250 ms
Warm-up time:? 15 min
Housing material:Die-cast zinc housing (ZNAL4CU1) acrylic glass (PMMA)
Connection type:Male connector, M12, 5-pin
Indication:2 x LED, LC display
Weight:200 g
footnote1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A 2) May not fall short of or exceed VS tolerances 3) Without load

Ambient data

Enclosure rating:IP 65
Protection class:III
Ambient temperature:Operation: -30 ... +65 °C, Storage: -40 ... +75 °C
Max. rel. humidity (not condensing):? 95 %
Vibration resistance:EN 60068-2-6 / EN 60068-2-64
Shock resistance:EN 60068-2-27
Typ. ambient light safety:40 klx