+7 (812) 200-96-95

LUT9 - LUT9U-11606 - 1047414

Производитель:  Sick
Артикул: sick147425
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Features

Sensing distance 1):150 mm
Operating range:50 mm 250 mm
Light source 2):LED
Type of light:Ultraviolet light
Wave length:375 nm
Light emission:Long side
Light spot size:5 mm x 12 mm
Light spot direction:Vertical
Receiving filters:KV 418 (standard)
Receiving range:450 nm ... 750 nm
Adjustment:Static 2-point teach-in with manual ?ne adjustment
Output function 3):Light switching
Dimensions (W x H x D):30.4 mm x 53 mm x 80 mm
Housing design (light emission):Rectangular
footnote1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 °C 3) L/D switching via teach-in or IO-Link

Mechanics/electronics

Ripple 1):< 5 Vpp
Power consumption 2):< 100 mA
Switching frequency 3):0.5 kHz, 2.5 kHz, 6.5 kHz, Adjustable
Response time 4):1 ms 200 µs 75 µs
Output type:NPN: HIGH = approx. VS / LOW ? 2 V PNP: HIGH = VS- ? 2 V / LOW approx. 0 V
Switching mode:PNP/NPN
Analog output QA:0 mA ... 13 mA
Output current Imax.:100 mA
Time delay:0 ms / 10 ms / 20 ms, Adjustable
Connection type:Connector M12, 5-pin
Protection class 5):II
Circuit protection:Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected
Enclosure rating:IP 67
Weight:400 g
Housing material:Metal, Zinc diecast
Supply voltage:10 V DC ... 30 V DC 6)
Fieldbus interface:-
footnote1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1, no time delay 4) Signal transit time with resistive load 5) Reference voltage DC 50 V 6) Limit values; operation in short-circuit protected network max. 8 A

Ambient data

Shock load:According to IEC 60068
Ambient operating temperature:-10 °C ... +55 °C
Ambient storage temperature:-25 °C ... +75 °C