+7 (812) 200-96-95

AFS/AFM60 SSI - AFM60E-S4AL004096 - 1037655

Производитель:  Sick
Артикул: sick145568
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Max. number of steps per revolution:4,096
Max. number of revolutions:4,096
Resolution power:4,096 x 4,096
Resolution:12 bit x 12 bit
Error limits:± 0.2 °
Repeatability (Ta not constant):0.002 °
Measuring step deviation:± 0.2 °
Measuring step:0.09 ° 360 ° / number of steps
Initialization time:50 ms 1)
footnote1) Valid positional data can be read once this time has elapsed

Механические параметры

Mechanical interface:Solid shaft with flat, Face mount flange
Shaft diameter:10 mm
Start up torque:0.5 Ncm (+20 °C)
Operating torque:0.3 Ncm (+20 °C)
Permissible Load capacity of shaft:40 N (axial), 80 N (radial)
Maximum operating speed:9,000 /min 1)
Moment of inertia of the rotor:6.2 gcm?
Bearing lifetime:3.0 x 10^9 revolutions
Max. angular acceleration:500,000 rad/s?
footnote1) Self warming of 3.3 K per 1000 revolutions/min when applying note working temperature range

Электрические параметры

Power consumption:0.5 W (without load)
Operating voltage range:4.5 V DC ... 32 V DC
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1) 1)
Connection type:Cable, 8-wire, universal, 3 m 2)
Code type:Gray
Code sequence:CW/CCW, parameter adjustable
Reverse polarity protection:1
footnote1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532. 2) The universal cable outlet is positioned in such a way, that it is possible to lay the cable in a radial or axial direction without kinking it

Interfaces

Electrical interface:SSI/Gray
Interface signals:Clock +, Clock -, Data +, Data-
Clock frequency:1 MHz 1)
SET (electronic adjustment):H-active (L ? 0 - 1,5 V, H ? 2,0 - Us V)
CW/CCW (counting sequence when turning):L-active (L ? 0 - 1,5 V, H ? 2,0 - Us V)
footnote1)

Ambient data

EMC:(according to EN 61000-6-2 and EN 61000-6-3) 1)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Working temperature range:0 °C ... +85 °C
Storage temperature range:-40 °C ... +100 °C, without package
Resistance to shocks:50 g, 6 ms (according to EN 60068-2-27)
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
footnote1)