+7 (812) 200-96-95

DFS60, Rotary - DFS60A-BAVA01200 - 1060276

Производитель:  Sick
Артикул: sick150275
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Error limits:± 0.03 °
Measuring step:Electronically/number of lines
Initialization time:30 ms
Pulses per revolution:1,200

Механические параметры

Mechanical interface:Blind hollow shaft
Shaft diameter:6 mm
Mass:0.2 kg
Start up torque:0.8 Ncm (+20 °C)
Operating torque:0.6 Ncm (+20 °C)
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.01 mm
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.05 mm
Maximum operating speed:6,000 /min
Moment of inertia of the rotor:40 gcm?
Bearing lifetime:3.6 x 10^10 revolutions
Max. angular acceleration:500,000 rad/s?
Shaft material:Metal

Электрические параметры

Electrical interface:10 V ... 32 V, TTL/RS422, 0-SET, Connector M23, 12-pin, radial
Connection type:Connector M23, 12-pin, radial
Maximum output frequency:820 kHz
Reference signal, number:1
Reference signal, position:90 °, electronically, gated with A and B
Operating voltage range:10 V ... 32 V
Load current max.:30 mA
Power consumption:0.7 W (without load)
MTTFd: mean time to dangerous failure:300 a (EN ISO 13849-1) 1)
footnote1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

Ambient data

EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Working temperature range:-30 °C ... +100 °C
Storage temperature range:-40 °C ... +100 °C, without package
Resistance to shocks:60 g (according to EN 60068-2-27)
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side 1)
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
footnote1) With mating connector fitted