Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Performance
Initialization time:
40 s
Error limits 'O' ring surface:
± 4 mm
Resolution:
1 mm
Smallest measuring step:
0.25 mm
Pulses per revolution:
200 1)
footnote
1) Pulses per 200 mm
Механические параметры
Mechanical interface:
Measuring drum, O ring surface
Mass:
0.42 kg
Maximum operating speed:
1,500 U/min
Bearing lifetime:
2 x 10^9 revolutions
Электрические параметры
Electrical interface:
4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m
Connection type:
Cable, 1.5 m
Supply voltage:
4.5 V ... 5.5 V
Output current:
30
Reference signal, number:
1
Reference signal, position:
90 °, electronically, gated with A and B
MTTFd: mean time to dangerous failure:
600 a (EN ISO 13849-1) 1)
footnote
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Ambient data
EMC:
EN 61000-6-2, EN 61000-6-3
Protection class standard:
IEC 60529
Air humidity:
90 % 1)
Working temperature range:
-10 °C ... +60 °C
Storage temperature range:
-40 °C ... +70 °C, without package
Resistance to shocks:
50 g, 7 ms (EN 60068-2-27)
Resistance to vibration:
20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
Enclosure rating:
IP 65
footnote
1) Condensation of the optical scanning not permitted