+7 (812) 200-96-95

KH53 - KHK53-AXB00354 - 1030072

Производитель:  Sick
Артикул: sick143730
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measuring length:0 m ... 354 m
Measurement range:354 m
Resolution:0.1 mm
Piston speed:6.6 m/s 1)
Measurement accuracy:± 1000 + ME (Tu-25° C) Tk µm 2)
Repeatability (Ta not constant):0.3 mm
footnote1) If the max. movement speed is exceeded or the read head cannot detect a measuring element the error message FF FF FE Hex is produced. 2) If the read head and measuring element are mounted within ± 1 mm of the nominal mounting distance in the N and Y directions. The figures quoted related to the accuracy within a measuring element with reference to the start of that measuring element. ME = length measuring element Tu = Ambient temperature °C

Механические параметры

Connection type:Connector M23, 12-pin
Mass:3.6 kg
Position tolerance:± 10 mm
Material:AlMgSiPbF28

Электрические параметры

Initialization time:2 s
Position forming time:0.8 ms
Supply voltage:10 V ... 32 V
Power consumption:250 mA
MTTFd: mean time to dangerous failure:31 a (EN ISO 13849) 1)
footnote1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

Interfaces

Electrical interface:SSI
Interface signals:Digital, serial
Interface for parametrization:Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex
Data format:SSI 24 bits format
Standard (default setting SSI standard):RS-422 off

Ambient data

EMC:(according to EN 61000-6-2 and EN 61000-6-4) 1)
Enclosure rating:IP 65 (IEC 60529), with mating connector inserted
Working temperature range:-20 °C ... +60 °C
Storage temperature range:-40 °C ... +85 °C
Resistance to shocks:30 g, 10 ms (DIN EN 60 068-2-27)
Resistance to vibration:10 g, 20 Hz ... 250 Hz (EN 60068-2-6)
footnote1)