1) These values were measred at an ambient temperature of 25 °C. There may be variations at other temperatures. 2) 3)
Электрические параметры
Initialization time:
Ca. 12 s 1)
Supply voltage:
10 V ... 32 V
Power consumption:
2 W
MTTFd: mean time to dangerous failure:
150 a 2) 3)
footnote
1) Valid positional data can be read once this time has elapsed. 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532. 3) The value applies to the mounted encoder
Interfaces
Electrical interface:
DeviceNet
Connection type:
Bus adaptor with cable screw fixings or connector, radial 1)
Address setting:
0 ... 63, DIP-switches or protocol
Protocol:
DeviceNet Specification Release 2.0
Bus termination:
Via DIP switches
SET (electronic adjustment):
Via PRESET push button or protocol
Encoder profile:
Generic Profile
Encoder:
Absolute encoders
footnote
1) Please order the bus adaptor seperately
Ambient data
EMC:
(according to EN 61000-6-2 and EN 61000-6-3)
Enclosure rating encoder:
IP 67
Enclosure rating mechanic:
IP 64
Resistance to shocks:
100 g, 6 ms (according to EN 60068-2-27)
Resistance to vibration:
20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Relative humidity / Condensation:
98 % (condensation of the optical scanning not permitted)
Working temperature range (encoder):
-20 °C ... +70 °C
Working temperature range (mechanics):
-30 °C ... +70 °C
Working temperature range (combination):
Wird definiert durch den hoheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik