LMS1xx / LMS12x / Security / Indoor - LMS123-10000 Security - 1044321
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Field of application: | Indoor, Security |
---|---|
Light source: | Infrared (905 nm) |
Laser class: | 1 (IEC 60825-1 (2007-3)) |
Field of view: | 270 ° |
Scanning frequency: | 25 Hz / 50 Hz |
Angular resolution: | 0.25 ° 0.5 ° |
Operating range: | 0.5 m ... 20 m |
Max. range with 10 % reflectivity: | 18 m |
Amount of evaluated echoes: | 2 |
Fog correction: | Yes |
Performance
Response time: | ? 20 ms |
---|---|
Detectable object shape: | Almost any |
Systematic error 1): | ± 30 mm |
Statistical error 2): | ± 12 mm |
Integrated application: | Field evaluation |
Number of field sets: | 10 fields |
Simultaneous processing cases: | 10 |
footnote | 1) 2) Typical value; actual value depends on environmental conditions. |
Interfaces
Function (Serial (RS-232)): | AUX |
---|---|
Data transmission rate (Serial (RS-232)): | 9.6 kBaud ... 115.2 kBaud |
Function (Ethernet): | Host |
Data transmission rate (Ethernet): | 10/100 Mbit |
Protocol (Ethernet): | TCP/IP, OPC |
Function (CAN bus): | Outputs extension |
PROFIBUS DP: | - |
PROFINET: | - |
DeviceNet: | - |
Switching inputs: | 4 |
Switching outputs: | 3 (2 relay, 1 digital) |
Optical indicators: | 1 7-segment display (plus 5 LEDs showing device status, contamination warning and initial condition) |
Mechanics/electronics
Electrical connection: | 1 x system plug with screw terminal block |
---|---|
Operating voltage: | 9 V DC ... 30 V DC |
Power consumption: | 20 W |
Housing color: | Signal white (RAL 9003) |
Enclosure rating: | IP 65 (EN 60529, Section 14.2.5) |
Protection class: | III (EN 50178 (1997;10)) |
Weight: | 1.1 kg, without connecting cables |
Dimensions: | 105 mm x 102 mm x 152 mm |
Ambient data
Object remission: | 2 % ... > 1,000 % (reflectors) |
---|---|
Electromagnetic compatibility (EMC): | EN 61000-6-2:2005 / EN 61000-6-4 (2007-01) |
Vibration resistance: | EN 60068-2-6 (1995-04) |
Shock resistance: | EN 60068-2-27 (1993-03) |
Ambient operating temperature: | 0 °C ... +50 °C |
Storage temperature: | -30 °C ... +70 °C |
Ambient light immunity: | 40,000 lx |
General notes
Note on use: | Not suitable for personnel protection |
---|