Features
Field of application: | Indoor |
---|
Version: | Short Range |
---|
Reading field: | Front |
---|
Light source: | Visible red light (650 nm) |
---|
Laser class: | 2, in standby mode laser class 1 according to IEC60825-1:2007 |
---|
Field of view: | 70 ° |
---|
Scanning frequency: | 180 Hz ... 500 Hz |
---|
Angular resolution: | 0.1° ... 1.0° |
---|
Operating range: | 0.7 m ... 3 m |
---|
Max. range with 10 % reflectivity: | 3 m |
---|
Performance
Response time: | ? 2 ms |
---|
Detectable object shape: | Almost any |
---|
Systematic error 1): | ± 4 mm |
---|
Statistical error 2): | ± 10 mm ± 3 mm |
---|
Integrated application: | Level Control |
---|
footnote | 1) 2) Typical value; actual value depends on environmental conditions. |
---|
Interfaces
Function (Serial (RS-232, RS-422)): | Host, AUX |
---|
Function (Ethernet): | Host |
---|
Data transmission rate (Ethernet): | 10 Mbit, half-duplex |
---|
Protocol (Ethernet): | TCP/IP |
---|
CAN bus: | - |
---|
PROFIBUS DP: | - |
---|
PROFINET: | - |
---|
DeviceNet: | - |
---|
Switching inputs: | 4 |
---|
Switching outputs: | 5 (4 x PNP / analog 1 x 4 mA ... 20 mA) |
---|
Optical indicators: | 6 LEDs |
---|
Mechanics/electronics
Operating voltage: | ? 24 V DC± 15 % |
---|
Power consumption: | 25 W |
---|
Housing: | Die-cast aluminum |
---|
Housing color: | Light blue (RAL 5012) |
---|
Enclosure rating: | IP 20 (DIN 40 050) 1) |
---|
Weight: | 2.3 kg |
---|
Dimensions: | 179 mm x 107 mm x 130 mm |
---|
footnote | 1) With plug cover IP 65 |
---|
Ambient data
Object remission: | 6.5 % ... 200 % |
---|
Electromagnetic compatibility (EMC): | EN 61000G6G2:2001 / EN 61000G6G4:2001 |
---|
Vibration resistance: | EN 60068G2G6, G27, G29, G64 |
---|
Shock resistance: | EN 60068G2G6, G27, G29, G64 |
---|
Ambient operating temperature: | 0 °C ... +40 °C |
---|
Storage temperature: | -20 °C ... +70 °C |
---|
General notes
Selectable region of interest (ROI): | From 50 mm x 3,000 mm to 1,000 mm x 1,750 mm |
---|
Number of columns: | Up to 50 equidistant or 30 freely positionable |
---|
Minimum column width: | 50 mm |
---|
Minimum detectable object: | 30 mm x 30 mm |
---|
Smallest height threshold above the container floor: | 20 mm |
---|
Switching threshold output: | Telegram, switch outputs or analog output |
---|
Output of height values in the columns: | Analog output, Telegram |
---|
Note on use: | Not suitable for personnel protection |
---|