+7 (812) 200-96-95

LMS5xx / LMS511 / Outdoor / Mid Range - LMS511-21100 Lite - 1054154

Производитель:  Sick
Артикул: sick148625
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Features

Field of application:Outdoor
Version:Mid Range
Variant:Lite
Resolution power:High Resolution
Light source:Infrared (905 nm)
Laser class:1 (IEC 60825-1 (2007-6)), eye-safe
Field of view:190 °
Scanning frequency:25 Hz / 35 Hz / 50 Hz / 75 Hz
Angular resolution:0.25 ° 0.5 ° 1 °
Heating:Yes
Operating range:0 m ... 80 m
Max. range with 10 % reflectivity:26 m
Spot size:4.7 mrad
Amount of evaluated echoes:2
Fog correction:Yes

Performance

Response time:? 13 ms
Detectable object shape:Almost any
Systematic error 1):± 25 mm (1 m ... 10 m) ± 35 mm (10 m ... 20 m)
Statistical error 2):± 7 mm (1 m ... 10 m) ± 9 mm (10 m ... 20 m)
Integrated application:Field evaluation
Number of field sets:4 fields
Simultaneous processing cases:4
footnote1) 2) Typical value; actual value depends on environmental conditions.

Interfaces

Function (Serial (RS-232, RS-422)):Host
Data transmission rate (Serial (RS-232, RS-422)):9.6 kBaud ... 500 kBaud
Function (Ethernet):Host
Data transmission rate (Ethernet):10/100 Mbit
Protocol (Ethernet):TCP/IP, OPC
CAN bus:-
PROFIBUS DP:-
PROFINET:-
DeviceNet:-
Function (USB):AUX
Data transmission rate (USB):9.6 kBaud ... 500 kBaud
Remark (USB):Mini-USB
Switching inputs:2
Switching outputs:3
Optical indicators:5 LEDs (additional 7-segment display)

Mechanics/electronics

Electrical connection:4 x M12 circular plug-in connector
Operating voltage:24 V DC
Power consumption:22 W, + 55 W heating (typical)
Housing color:Gray (RAL 7032)
Enclosure rating:IP 67 (EN 60529, Section 14.2.7)
Protection class:III (EN 60529, Section 14.2.7)
Weight:3.7 kg
Dimensions:160 mm x 155 mm x 185 mm

Ambient data

Object remission:2 % ... > 1,000 % (reflectors)
Electromagnetic compatibility (EMC):EN 61000-6-2:2005 / EN 61000-6-3 (2007-03)
Vibration resistance:EN 60068-2-6 (1995-04)
Shock resistance:EN 60068-2-27 (1993-03) / EN 60068-2-29 (1993-04)
Ambient operating temperature:-30 °C ... +50 °C
Storage temperature:-30 °C ... +70 °C
Ambient light immunity:70,000 lx

General notes

Note on use:Not suitable for personnel protection