+7 (812) 200-96-95

S300 Professional, Laser scanner - S30B-3011DA - 1056429

Производитель:  Sick
Артикул: sick149119
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Функции

Expanded measured data output (CMS):-

Технические характеристики

Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:III (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... +50 °C
Dimensions (W x H x D):102 mm x 152 mm x 106 mm
Weight:1.2 kg
Scan angle:270 °
Protective field range:3 m
Maximum warning field range:8 m
Number of field sets:8
Type of field set:Triple field sets
Number of monitoring cases:32
Response time:80 ms 1)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:30 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 30 V DC
Number of universal I/Os:5 2)
Number of EDM inputs:1 3)
Number of reset-/restart inputs:1 4)
Number of static control inputs:3 5)
Number of static control inputs with EFI:5 6)
Number of dynamic control inputs:2 7)
Number of stand-by inputs:1
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:3 8)
Maximum output current:250 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
footnote1) Depending on basic response time and multiple sampling 2) Freely programmable, e.g., input external device monitoring, input reset, contamination warning, reset required 3) 4) Availability depends on the configuration of the universal I/Os 5) 2+1; additional input only available if reset and reset required are not used. 6) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise three. 7) Two of the static swichting signals can be used either as dynamic or as static switching signals. 8) Freely programmable, e.g., warning field, contamination, reset required