+7 (812) 200-96-95

S3000 Expert, Sensor head with I/O module - S30A-7011GB - 1052109

Производитель:  Sick
Артикул: sick148102
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Функции

Number of simultaneously monitored protective fields:? 4 1)
footnote1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway.

Технические характеристики

Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... +50 °C
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Weight:3.3 kg
Scan angle:190 °
Protective field range:7 m
Maximum warning field range:49 m
Number of field sets:32 1)
Type of field set:Dual field sets, Triple field sets
Number of monitoring cases:32 2)
Response time:60 ms 3)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:49 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of EDM inputs:1
Number of reset-/restart inputs:1
Number of static control inputs:4
Number of static control inputs with EFI:5 4)
Number of dynamic control inputs:2 5)
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:3 6)
Maximum output current:500 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
footnote1) In dual field mode 32, in triple field mode 21 field sets 2) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise 16. 3) Depending on basic response time and multiple sampling 4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise four. 5) Two of the static swichting signals can be used either as dynamic or as static switching signals. 6) Freely programmable, e.g., warning field, contamination, reset required