+7 (812) 200-96-95

S3000 Standard, I/O module - S30A-XXXXBA - 2026801

Производитель:  Sick
Артикул: sick153310
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Функции

Number of simultaneously monitored protective fields:? 4 1)
Incremental encoder inputs:-
Expanded measured data output (CMS):-
footnote1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway.

Технические характеристики

Enclosure rating:IP 65 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... +50 °C
Response time:60 ms 1)
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of EDM inputs:1
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:3 2)
Maximum output current:500 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
footnote1) Depending on basic response time and multiple sampling 2) Freely programmable, e.g., warning field, contamination, reset required