M2000 Standard A/P - PSR01-1501 - 1016677
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Applications
Hazardous area protection (horizontal): | - |
---|
Functions-Sender/receiver in one housing
System construction: | Active/passive system |
---|---|
Restart interlock: | - |
External device monitoring: | - |
Beam coding: | - |
Muting with: | Flexi Classic, Flexi Soft |
Configurable scanning range: | - |
Configuration method: | Hard wired |
Safe device communication via EFI/SDL: | - |
Technical Data-Sender/receiver in one housing
Количество лучей: | 1 |
---|---|
Scanning range from ... to: | 0 m ... 6 m |
Type: | Type 2 (according to IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | Category 2 (EN ISO 13849) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 2.2 * 1E-08 |
TM (mission time): | 20 a |
Housing cross-section: | 48 mm x 40 mm |
Maximum response time: | 7 ms |
Supply voltage typical, from, to: | 24 V, 19.2 V, 28.8 V |
Display elements: | 7-segment |
Maximum power consumption: | 7.5 W |
Maximum switching voltage: | Uv-2.25 V |
Maximum switching current: | 500 mA |
Protection class: | III |
Enclosure rating: | IP 65 (according to EN 60529) |
System connection: | Hirschmann plug |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Maximum connection cable cross-section: | 1 mm? |
Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (according to IEC 68-2-29) |
Test rate (internal test): | 13 /s (EN ISO 13849) |
Maximum demand rate: | 8 /min (EN ISO 13849) |
Resolution: | 500 mm |
Technical Data-Mirror
Resolution: | 500 mm |
---|