Safety-related parameters

Type:Type 2 (IEC 61496)
Safety integrity level:SIL1 (IEC 61508) SILCL1 (EN 62061)
Category:Category 2 (EN ISO 13849)
Test rate (internal test):47 /s
Maximum demand rate:28 /min (EN ISO 13849) 1)
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics! 2)
PFHd:Cascaded systems: 5.2 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Safe state in the event of a fault:At least one OSSD is in the OFF state.
footnote1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out. 2) The performance level does not contain any specific requirements on aspects such as the optical characteristics. For more detailed information on this topic, see page xx.

Функции

Restart interlock (delivery status):Deactivated
External device monitoring (delivery status):Deactivated
Safe SICK device communication via EFI/SDL:-

Features

Resolution:34 mm
Protective field height:420 mm
Scanning range:0 m ... 6 m
Typical range:0 m ... 8 m
Response time:? 13 ms 1)
Synchronization:Optical, without separate synchronization
footnote1) Standalone devices, no cascaded systems. Other response times see operating instructions.

Механические параметры

Housing cross-section (incl. system connection):15 mm x 32 mm
Housing material:Aluminum alloy ALMGSI 0.5
Weight:155 g

Электрические параметры

Protection class:III (EN 61140)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Residual ripple:? 10 % 1)
Power consumption:? 3 A 2)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Switching voltage LOW:2 V DC
Switching current:300 mA
footnote1) Within the limits of VS 2) Maximum power consumption of a host/guest/guest system with 1,200 mm protective field height and a resolution of 14 mm 3) Applies to the voltage range between -30 V and +30 V

Interfaces

Electrical connection:Connector M12, 5-pin
Connection type extension connection:Female connector M12, 5-pin
Cable length:350 mm
Conductor cross-section:0.34 mm?
Permitted cable length:? 20 m 1)
Configuration method:Hard wired
Display elements:LEDs
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET 2)
footnote1) 2) For further information on Flexi Soft, please see sens:Control - safe control solutions product catalog or -> www.sick.com/FlexiSoft

Ambient data

Enclosure rating:IP 65 (EN 60529)
Ambient operating temperature:-20 °C ... +55 °C
Storage temperature:-25 °C ... +70 °C
Air humidity:15 % ... 95 %, non-condensing
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance:10 g, 16 ms (EN 60068-2-27)