Safety-related parameters

Safety integrity level:SIL3 (IEC 61508) SILCL3 (EN 62061)
Category:Category 4 (EN ISO 13849-1)
Performance level:PL e (EN ISO 13849-1)
PFHd:0.76 * 1E-09 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Safe state in the event of a fault:The sensor cascade has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.

Функции

Cross-circuit:Monitoring via OSSD device
Short-circuit:Monitoring via OSSD device
Discrepancy errors:Monitoring via Flexi Loop node
Sequence errors:Monitoring via Flexi Loop node

Механические параметры

Dimensions (W x H x D):68.15 mm x 45 mm x 18 mm
Weight:28 g (± 5 %)

Электрические параметры

Protection class:III (EN 61140)
Type of supply voltage:SELV
Supply voltage Vs:24 V DC (16.8 V DC ... 30 V DC)
Power consumption:45 mA

Interfaces

Safety device connection:Safety sensor with dual-channel OSSD outputs
Flexi Loop input:To connect a Flexi Loop predecessor module, or to connect a Flexi Loop string with the safety controller Flexi Soft.
Flexi Loop output:To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element.
Connection type safety device:Female connector M12, 5-pin
Connection type Flexi Loop input:Male connector M12, 5-pin
Connection type Flexi Loop output:Female connector M12, 5-pin
Number of non-safe inputs:1
IO-Link:-

Ambient data

Enclosure rating:IP 65, IP 67 (EN 60529)
Ambient operating temperature:-25 °C ... +55 °C
Storage temperature:-25 °C ... +70 °C
Electromagnetic compatibility (EMC):Class A (EN 61000-6-2, EN 55011)
Shock resistance (continuous shock):10 g, 16 ms (EN 60068-2-64)
Shock resistance (single shock):30 g, 11 ms (EN 60068-2-27)