Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Applications
Type of switching amplifier:
Contact expansion module
Emergency stop pushbuttons:
-
Safety switches:
-
Safety Switch with mechanical lock:
-
Two-hand control systems:
-
Pressure sensitive mats:
-
Opto-electronic protective devices:
-
Opto-electronic protective devices without RES/EDM:
-
Opto-electronic protective devices with RES/EDM:
-
System part:
Safety relays
Функции
Cross-circuit detection:
-
Reset/restart:
Automatic
External device monitoring:
-
Технические характеристики
Safety integrity level:
SIL3 (IEC 61508), SILCL3 (IEC 62061) 1)
Category:
Category 4 (EN ISO 13849) 2)
Performance level:
PL d (EN ISO 13849) 3)
B10d parameter:
1* 1E 06 switching cycles (AC-15, 230 V, I = 0,5 A) 3.5*1E 05 switching cycles (DC-13, 24 V, I = 2 A) 1.2 * 1E 06 switching cycles (DC-13, 24 V, I = 0,5 A)
PFHd:
2.0 * 1E-07
TM (mission time):
20 a
Width:
22.5 mm
Contact type:
Positively driven
Number of enable current contacts:
4
Number of signalling current contacts:
2
Operating voltage AC:
24 V AC
Operating voltage DC:
24 V DC
Maximum power consumption AC:
2.7 VA
Maximum power consumption DC:
1.5 W
Type of output:
Relay contacts
Rated operating current (voltage):
6 A (230 V AC) 360 switching cycles/h 6 A (24 V DC) 360 switching cycles/h 3 A (24 V DC) 3600 switching cycles/h
Maximum switching current:
6 A
Maximum total current:
12 A
Mechanical life (relay contacts):
1*1E 07 switching cycles
Electrical life (relay contacts):
2* 1E 06 switching cycles, dependent upon loading, details see operating instructions
Enclosure rating:
IP 20
Ambient operating temperature from ... to:
-25 °C ... 55 °C
Connection type:
Plug-in terminals
footnote
1) 2) 3) If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit