Applications
Type of switching amplifier:
Main unit
Safety Switch with mechanical lock:
-
Two-hand control systems:
-
Pressure sensitive mats:
-
Opto-electronic protective devices:
-
Opto-electronic protective devices without RES/EDM:
-
Opto-electronic protective devices with RES/EDM:
-
System part:
Safety relays
Функции
Input circuit::
Single-channel
Cross-circuit detection:
-
Reset/restart:
Manual / automatic / configurable
Технические характеристики
Safety integrity level:
SIL3 (IEC 61508), SILCL3 (IEC 62061) 1)
Category:
Category 4 (EN ISO 13849) 2)
Performance level:
PL e (EN ISO 13849) 3)
B10d parameter:
1.26 * 1E 06 switching cycles (AC-15, 230 V, I = 1.5 A) 5.9*1E 06 switching cycles (AC-15, 230 V, I = 0.75 A) 4.35*1E 05 switching cycles (DC-13, 24 V, I = 2.5 A) 1*1E 07 switching cycles (DC-13, 24 V, I = 0.63 A)
PFHd:
3.0 * 1E-08
TM (mission time):
14 a
Stop category:
0, EN 60204
Width:
22.5 mm
Contact type:
Positively driven
Number of enable current contacts:
2
Number of signalling current contacts:
1
Operating voltage AC:
115 V AC
Maximum power consumption AC:
2.7 VA
Type of output:
Relay contacts
Rated operating current (voltage):
4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h
Maximum switching current:
6 A
Maximum total current:
12 A
Mechanical life (relay contacts):
1*1E 07 switching cycles
Electrical life (relay contacts):
2* 1E 06 switching cycles, dependent upon loading, details see operating instructions
Enclosure rating:
IP 20
Ambient operating temperature from ... to:
-25 °C ... 55 °C
Connection type:
Screw-type terminals
footnote
1) 2) 3) Maximum category 2, performance level d, safety integrity level SIL2, SILCL2 in the application