Applications

Type of switching amplifier:Main unit
Safety Switch with mechanical lock:-
Two-hand control systems:-
Pressure sensitive mats:-
Opto-electronic protective devices:-
Opto-electronic protective devices without RES/EDM:-
Opto-electronic protective devices with RES/EDM:-
System part:Safety relays

Функции

Input circuit::Single-channel
Cross-circuit detection:-
Reset/restart:Manual / automatic / configurable

Технические характеристики

Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061) 1)
Category:Category 4 (EN ISO 13849) 2)
Performance level:PL e (EN ISO 13849) 3)
B10d parameter:1.26 * 1E 06 switching cycles (AC-15, 230 V, I = 1.5 A) 5.9*1E 06 switching cycles (AC-15, 230 V, I = 0.75 A) 4.35*1E 05 switching cycles (DC-13, 24 V, I = 2.5 A) 1*1E 07 switching cycles (DC-13, 24 V, I = 0.63 A)
PFHd:3.0 * 1E-08
TM (mission time):14 a
Stop category:0, EN 60204
Width:22.5 mm
Contact type:Positively driven
Number of enable current contacts:2
Number of signalling current contacts:1
Operating voltage DC:24 V DC
Maximum power consumption DC:1.6 W
Type of output:Relay contacts
Rated operating current (voltage):4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h
Maximum switching current:6 A
Maximum total current:12 A
Mechanical life (relay contacts):1*1E 07 switching cycles
Electrical life (relay contacts):2* 1E 06 switching cycles, dependent upon loading, details see operating instructions
Enclosure rating:IP 20
Ambient operating temperature from ... to:-25 °C ... 55 °C
Connection type:Screw-type terminals
footnote1) 2) 3) Maximum category 2, performance level d, safety integrity level SIL2, SILCL2 in the application