Поставляем Датчик уровня TDR TDR level sensor - LFP0700-N1NMB - 1059413 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Medium: | Fluids |
|---|---|
| Measurement: | Switch, Continuous |
| Probe length: | 700 mm |
| Process pressure: | -1 bar ... 16 bar |
| Process temperature: | -20 °C ... +150 °C |
| 3-A: | - |
| Design: | Standard |
| Resolution: | < 2 mm |
|---|---|
| Accuracy of sensor element: | ± 5 mm |
| Repeatability: | ? 2 mm |
| Dielectricity constant: | ? 1.8 with coaxial tube, ? 5 for mono probe |
| Inactive area at process connector: | 25 mm 1) |
| Inactive area at probe end: | 10 mm 2) |
| Conductivity: | No limitation |
| Response time: | < 400 ms 3) |
| MTTF: | 194.3 a (EN ISO 13849-1) |
| footnote | 1) With parameterized tank with water under reference conditions, otherwise 40 mm 2) With water under reference conditions 3) Depending on measuring mode (high speed < 400 ms, high accuracy < 2,800 ms). |
| Housing material: | 303 |
|---|---|
| Max.probe load: | 6 Nm |
| Process connection: | ?' NPT |
| Wetted parts: | 316L (Ra ? 0,8 µm), PEEK |
| Housing design: | With PMMA viewing window |
| Temperature drift: | < 0.1 mm/K |
|---|---|
| Enclosure rating: | IP 67: EN 60529, IP 69K: EN 40050 |
| Supply voltage: | 12 V DC ... 30 V DC 1) |
| Power consumption: | ? 75 mA at 24 V DC without output load |
| Protection class: | III |
| Initialization time: | ? 2 s |
| Output load: | 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V |
| Upper signal level: | 20 mA ... 20.5 mA |
| Lower signal level: | 3.8 mA ... 4 mA |
| Hysteresis: | Min. 2 mm, free adjustable |
| Output current: | < 100 mA |
| Signal voltage HIGH: | Vs - 2 V |
| Signal voltage LOW: | ? 2 V |
| Capacitive load: | 100 nF |
| Inductive load: | < 1 H |
| Connection type: | Round connector M12 x 1, 5-pin |
| EMC: | EN 61326-1:2006, 2004/108/EG |
| Interference resistance: | EN 61000-6-2:2005 |
| Interference emission: | EN 61000-6-4:2007 |
| Single- and continuous shock: | EN 60068-2-27 |
| footnote | 1) All connections are polarity protected. All outputs are overload and short-circuit protected. |
| Ambient operating temperature: | -20 °C ... +60 °C |
|---|---|
| Ambient storage temperature: | -40 °C ... +80 °C |