Поставляем Датчик с прямоугольным корпусом Rectangular housing, CQ28 - CQ28-10NNP-KW1 - 6030133 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Design: | Rectangular |
|---|---|
| Dimensions (W x H x D): | 28 mm x 46 mm x 5.5 mm |
| Sensing range Sn: | 10 mm |
| Assured sensing range Sa: | 7.2 mm |
| Installation type: | Non-flush |
| Switching frequency: | 10 Hz |
| Output type: | NPN |
| Output function: | NC or NO |
| Electrical wiring: | DC 4-wire |
| Enclosure rating: | IP 68 1) |
| Electrical connection: | Cable, 4-wire, 2 m 2) |
| Adjustment: | Single teach-in button cable, Sensitivity |
| footnote | 1) According to EN 60529 2) Do not bend below 0 °C |
| Housing material: | Plastic |
|---|---|
| Supply voltage: | 10 V DC ... 30 V DC |
| Residual ripple: | ? 10 % |
| Voltage drop: | ? 2.5 V DC 1) |
| Power consumption: | ? 12 mA 2) |
| Time delay before availability: | ? 300 ms |
| Repeatability: | ? 5 % 3) 4) |
| Temperature drift (of Sr): | ± 10 % |
| EMC: | According to EN 60947-5-2 5) |
| Output current Ia: | ? 200 mA |
| Cable material: | PVC |
| Conductor cross-section: | 0.14 mm? |
| Shock and vibration resistance: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
| Ambient temperature operation: | -20 °C ... +85 °C |
| Ambient storage temperature: | -40 °C ... +85 °C |
| Housing cap material: | PBT |
| UL File No.: | NRKH.E191603 |
| footnote | 1) At Ia max 2) Without load 3) Of Sr 4) Ub and Ta constant 5) In EMC critical applications, conducted interference levels may lie in the frequency range of the oscillator. This can cause changes to the output signal.(see operating instructions) |
| Note: | The values are reference values which may vary |
|---|---|
| Metal: | 1 |
| Water: | 1 |
| PVC: | Ca. 0.4 |
| Oil: | Ca. 0.25 |
| Remark: | Associated graphic see 'Installation' |
|---|---|
| A: | 27.6 mm |
| B: | 27.6 mm |