Поставляем Датчик расстояния DL100 Dx100, DL100 Pro - DL100-21AA2102 - 1052686 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Measurement range: | 0.15 m ... 100 m, On reflective tape 'Diamond Grade' |
|---|---|
| Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm |
| Repeatability 1): | 0.5 mm |
| Accuracy 2): | ± 2 mm |
| Light source 3): | Laser, red |
| Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) |
| Acceleration (max.): | 15 m/s? |
| Internal measurement cycle: | 1 ms |
| Max. movement speed: | 30 m/s |
| Dead time: | 2 ms |
| Laser class: | 2 (EN 60825-1 / CDRH) |
| Output time: | Synchronous to PLC request (dependent on interfaces) |
| footnote | 1) Statistical error 1 ?, environmental conditions constant, min. warm-up time 10 min 2) From 150 mm ... 180 mm measuring range the accuracy can reach ± 4 mm 3) Average service life of 100,000 h at TA = +25 °C |
| Data interface: | PROFIBUS DP |
|---|---|
| Output type 1): | B (push/pull) MF1, MF2 |
| Multifunctional input (MF) 2): | 1 x MF1 |
| footnote | 1) HIGH > VS - 3 V / LOW < 2 V 2) HIGH > 12 V / LOW < 3 V |
| Supply voltage Vs: | DC 18 V ... 30 V, limit values |
|---|---|
| Ripple 1): | 5 Vpp |
| Initialization time 2): | Typ. 1.5 s |
| Indication: | 6 digit 5 x 7 dot matrix display, LEDs |
| Weight 3): | Ca. 800 g ... 1,600 g |
| Output current IA 4): | ? 100 mA |
| Power consumption: | At 24 V DC < 250 mA |
| Connection type: | Male connector, M12, SPEEDCON™ compatible |
| Housing material: | Aluminum/zinc die-cast |
| Modulation frequency: | Fix |
| footnote | 1) May not fall short of or exceed VS tolerances 2) After loss of reflector < 40 ms 3) Without mounting bracket: approx. 800 g, with mounting bracket: approx. 1,600 g 4) Short circuit/overload protected. Max. 100 nF / 20 mH |
| Enclosure rating: | IP 65 |
|---|---|
| Protection class: | III |
| Effect of air pressure: | 0.3 ppm/hPa |
| Effect of air temperature: | 1 ppm/K |
| Temperature drift: | Typ. 0.1 mm/K |
| Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
| Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
| Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
| footnote | 1) Temperatures < -10 °C require warm-up time of typ. 7 minutes. 2) This is a Class A device. This device can cause radio interference in living quarters. |