| Ripple 1): | ? 5 Vpp |
|---|
| Power consumption 2): | < 6 W |
|---|
| Output type: | PNP: HIGH = VS - ? 2 V / LOW < 0,5 V |
|---|
| Status output: | PNP: HIGH = VS - ? 2 V / LOW < 0,5 V 3) |
|---|
| Switching mode: | PNP |
|---|
| Output current Imax. 4): | < 100 mA |
|---|
| Input, teach-in (ET): | PNP: Teach: U = 12 V ... < UV, Run: U < 2 V |
|---|
| Input, blanking input (AT) 5): | PNP: blanked: U = 12 V ... < Uv, free-running U < 2 V |
|---|
| Initialization time: | < 10 s |
|---|
| Retention time (ET): | ? 6 s, non-volatile memory |
|---|
| Connection type 6): | Ethernet connection M12, 4-pin Connector M12, 12-pin |
|---|
| Protection class: | III |
|---|
| Circuit protection: | VS connections reverse-polarity protected, Output Q short-circuit protected, Interference suppression |
|---|
| Enclosure rating: | IP 65, IP 65 |
|---|
| Weight: | 325 g |
|---|
| Housing material: | Metal |
|---|
| Encoder resolution: | 100 µm ... 400 µm (in 1 µm) |
|---|
| Encoder input: | Differentiel: 4,5 V - 5,5 V / TTL / RS-422, Single ended: 12 V - 30 V / HTL / push-pull |
|---|
| Supply voltage: | 12 V DC ... 30 V DC 7) |
|---|
| Ambient light immunity: | 30,000 lx |
|---|
| Fieldbus interface: | EtherNet/IP |
|---|
| footnote | 1) May not exceed or fall short of VS tolerances 2) Without load 3) Detailed description of the status output in operating manual 4) Sum Iout = Q + Q status 5) Fade-out of identical areas 6) Use drilled and shielded cable 7) Limit values; operation in short-circuit protected network max. 8 A |
|---|