| Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
|---|
| Enclosure rating: | IP 65 (EN 60529) |
|---|
| Protection class: | III (EN 50178) |
|---|
| Type: | Type 3 (IEC 61496) |
|---|
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
|---|
| Category: | Category 3 (EN ISO 13849) |
|---|
| Performance level: | PL d (EN ISO 13849) |
|---|
| PFHd: | 8.0 * 1E-08 (EN ISO 13849) |
|---|
| TM (mission time): | 20 a (EN ISO 13849) |
|---|
| Ambient operating temperature: | -10 °C ... +50 °C |
|---|
| Dimensions (W x H x D): | 102 mm x 116 mm x 105 mm |
|---|
| Weight: | 0.8 kg, without connecting cables |
|---|
| Scan angle: | 270 ° |
|---|
| Protective field range: | 2 m |
|---|
| Maximum warning field range: | 8 m |
|---|
| Number of field sets: | 16 |
|---|
| Type of field set: | Triple field sets |
|---|
| Response time: | 80 ms 1) |
|---|
| Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, configurable |
|---|
| Distance measuring range: | 30 m |
|---|
| Number of multiple samplings: | Configurable 2 ... 16 |
|---|
| Electrical connection: | Cable, 250 mm, with male connector M12, 7-pin |
|---|
| Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC |
|---|
| Number of static control inputs with EFI: | 5 2) |
|---|
| Number of stand-by inputs: | 1 3) |
|---|
| Number of outputs: | Depends on the configuration of the connected EFI device |
|---|
| Configuration and diagnostics interface: | RS-232 |
|---|
| footnote | 1) Depending on basic response time and multiple sampling 2) 3) Can only be used in EFI system network, e.g., with a Flexi Soft safety controller or another S300 or S3000 safety laser scanner |
|---|