| Number of simultaneously monitored protective fields: | ? 4 1) |
|---|---|
| Incremental encoder inputs: | - |
| Expanded measured data output (CMS): | - |
| footnote | 1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway. |
| Enclosure rating: | IP 65 (EN 60529) |
|---|---|
| Protection class: | II (EN 50178) |
| Type: | Type 3 (IEC 61496) |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
| Category: | Category 3 (EN ISO 13849) |
| Performance level: | PL d (EN ISO 13849) |
| PFHd: | 8.0 * 1E-08 (EN ISO 13849) |
| TM (mission time): | 20 a (EN ISO 13849) |
| Ambient operating temperature: | -10 °C ... +50 °C |
| Response time: | 60 ms 1) |
| Electrical connection: | System plug with or without connecting cable |
| Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
| Number of EDM inputs: | 1 |
| Number of safe outputs: | 2, Safety outputs (OSSD) |
| Number of application diagnostic outputs: | 3 2) |
| Maximum output current: | 500 mA |
| Configuration and diagnostics interface: | RS-232 |
| Data interface: | RS-422 |
| footnote | 1) Depending on basic response time and multiple sampling 2) Freely programmable, e.g., warning field, contamination, reset required |