Поставляем Световая завеса безопасности miniTwin2 как каскадный хост или гостевое устройство - не как конечный каскад miniTwin2 as a cascaded host or guest device - not as a cascade end unit - C2MT-04814BBC04DE0 - 1207872 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Type: | Type 2 (IEC 61496) |
|---|---|
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
| Category: | Category 2 (EN ISO 13849) |
| Test rate (internal test): | 47 /s |
| Maximum demand rate: | 28 /min (EN ISO 13849) 1) |
| Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! 2) |
| PFHd: | Cascaded systems: 5.2 * 1E-08 (EN ISO 13849) |
| TM (mission time): | 20 a (EN ISO 13849) |
| Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
| footnote | 1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out. 2) The performance level does not contain any specific requirements on aspects such as the optical characteristics. For more detailed information on this topic, see page xx. |
| Restart interlock (delivery status): | Deactivated |
|---|---|
| External device monitoring (delivery status): | Deactivated |
| Safe SICK device communication via EFI/SDL: | - |
| Resolution: | 14 mm |
|---|---|
| Protective field height: | 480 mm |
| Scanning range: | 0 m ... 6 m |
| Typical range: | 0 m ... 8 m |
| Response time: | ? 14 ms 1) |
| Synchronization: | Optical, without separate synchronization |
| footnote | 1) Standalone devices, no cascaded systems. Other response times see operating instructions. |
| Housing cross-section (incl. system connection): | 15 mm x 32 mm |
|---|---|
| Housing material: | Aluminum alloy ALMGSI 0.5 |
| Weight: | 175 g |
| Protection class: | III (EN 61140) |
|---|---|
| Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
| Residual ripple: | ? 10 % 1) |
| Power consumption: | ? 3 A 2) |
| Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored 3) |
| Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
| Switching voltage LOW: | 2 V DC |
| Switching current: | 300 mA |
| footnote | 1) Within the limits of VS 2) Maximum power consumption of a host/guest/guest system with 1,200 mm protective field height and a resolution of 14 mm 3) Applies to the voltage range between -30 V and +30 V |
| Electrical connection: | Connector M12, 5-pin |
|---|---|
| Connection type extension connection: | Female connector M12, 5-pin |
| Cable length: | 350 mm |
| Conductor cross-section: | 0.34 mm? |
| Permitted cable length: | ? 20 m 1) |
| Configuration method: | Hard wired |
| Display elements: | LEDs |
| Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET 2) |
| footnote | 1) 2) For further information on Flexi Soft, please see sens:Control - safe control solutions product catalog or -> www.sick.com/FlexiSoft |
| Enclosure rating: | IP 65 (EN 60529) |
|---|---|
| Ambient operating temperature: | -20 °C ... +55 °C |
| Storage temperature: | -25 °C ... +70 °C |
| Air humidity: | 15 % ... 95 %, non-condensing |
| Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
| Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |