Поставляем Считывание кодов по изображению Lector®65x / Lector®652 Flex - V2D652R-MCXXA6 Flex - 1063404 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Reading field: | Side |
|---|---|
| Focus: | Adjustable focus (manually) |
| Sensor: | CMOS matrix sensor, gray scale values |
| Sensor resolution: | 2,048 px x 1,088 px |
| Code resolution: | ?0.1 mm 1) |
| Reading distance: | 300 mm ... 2,200 mm, depends on lens used 2) |
| Scanning frequency: | 70 Hz, at 2 megapixels resolution |
| Light source: | Lighting LEDs: - (to be ordered separately as accessory) aiming laser: visible red light (? = 630 nm ... 680 nm) |
| Laser class: | 1M (IEC 60825-1 (2007-3)), complies with 21 CFR 1040.10 except for the tolerance according to “Laser Notice No. 50” from June 24, 2007 |
| footnote | 1) Depends on lens used 2) For details see field of view |
| Bar code types: | Interleaved 2 of 5, Codabar, Code 128, Code 32, Code 39, Code 93, GS1 DataBar, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN |
|---|---|
| 2D code types: | Data Matrix ECC200, GS1 Data-Matrix, MaxiCode, QR code |
| Internal image storage: | 512 MB |
| Code qualification: | On the basis of ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 18004 |
| Stacked code types: | PDF417 |
| Function (Serial (RS-232, RS-422)): | Host, AUX |
|---|---|
| Data transmission rate (Serial (RS-232, RS-422)): | 300 Baud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) |
| Remark (USB): | USB 2.0 |
| Function (Ethernet): | Host, AUX, image transmission |
| Data transmission rate (Ethernet): | 10/100/1,000 Mbit/s |
| Protocol (Ethernet): | TCP/IP, FTP (image transmission), EtherNet/IP, PROFINET (optional via external connection module CDF600-2) |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer/Server) |
| Data transmission rate (CAN bus): | 20 kbit/s ... 1 Mbit/s |
| Protocol (CAN bus): | CSN (SICK CAN Sensor Network) |
| Remark (PROFIBUS DP): | Optional via external connection module (CDF600-2) |
| DeviceNet: | - |
| Acoustic indicators: | Beeper/buzzer (can be switched off, can be assigned a function to signal a result) |
| Control elements: | 2 buttons (choose and start/stop functions) |
| Optical indicators: | 21 LEDs (10 x status display, 10 x LED bar graph, 1 green feedback spot) |
| Switching inputs: | 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB650/CDM420) |
| Switching outputs: | 6 (CDB650: “Result 1”, “Result 2”, “Result 3”, “Result 4”, 2 external outputs via CMC600 or CDM420: “Result 1”, “Result 2”, 2 external outputs via CMC600 or cable with open end “Result 1”, “Result 2”, “Result 3”, “Result 4”) |
| Reading pulse: | Auto pulse, CAN, Ethernet, Non-powered, Presentation mode, Switching inputs, Serial interface |
| Memory card: | MicroSD memory card (flash card) max. 16 GB, optional |
| Configuration software: | SOPAS ET |
| Operating voltage: | 24 V DC± 20 % |
|---|---|
| Power consumption: | Typ. 20 W, ± 20 % |
| Electrical connection: | 1 x M12, 17-pin plug (serial, CAN, I/Os, power supply), 1 x M8, 4-pin socket (USB), 2 x M12, 8-pin socket (Ethernet, P1 not yet with function) |
| Housing: | Die-cast aluminum |
| Housing color: | Light blue (RAL 5012) |
| Weight: | 635 g |
| Dimensions: | 142 mm x 89 mm x 46 mm 1) |
| Enclosure rating: | IP 65 (EN 60529 (1991-10), EN 60529/A2 (2002-02)) |
| Protection class: | III |
| Lens: | Exchangeable (C-mount), to be ordered separately as accessory |
| footnote | 1) Only housing without lens and protective hood |
| Electromagnetic compatibility (EMC): | EN 61000-6-2 (2005-08) / EN 61000-6-3 (2007-01) |
|---|---|
| Shock resistance: | EN 60068-2-6 |
| Electrical safety: | EN 60950-1 (2011-01) |
| Ambient operating temperature: | 0 °C ... +50 °C |
| Storage temperature: | -20 °C ... +70 °C |
| Permissible relative humidity: | 90 %, non-condensing |
| Ambient light immunity: | 2,000 lx, on code |