Поставляем Контроллер безопасности Flexi Soft Motion Control module, Flexi Soft Drive Monitor - FX3-MOC000000 - 1062344 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
|---|---|
| Category: | Category 4 (EN ISO 13849-1) |
| Performance level: | PL e (EN ISO 13849-1) |
| PFHd: | EN ISO 13849 |
| TM (mission time): | 20 a (EN ISO 13849) |
| Safe state in the event of a fault: | The safety-related data is logic 0. |
| Dimensions (W x H x D): | 22.5 mm x 96.5 mm x 120.8 mm |
|---|---|
| Weight: | 120 g |
| Protection class: | III (EN 61140) |
|---|---|
| Power consumption: | ? 2.5 W 1) |
| Output voltage for encoder: | 24 V |
| footnote | 1) Via FLEXBUS+, without encoder voltage supply |
| Connection type: | Male connector, Micro D-Sub, 15-pin |
|---|---|
| Encoder interface: | A/B incremental encoder, HTL A/B incremental encoder, RS-422 A/B incremental encoder, TTL Sin/Cos encoder SSI encoder |
| Data interface: | Internal bus (FLEXBUS+) |
| Protection class housing: | IP 40 (EN 60529) |
|---|---|
| Enclosure rating terminals: | IP 20 (EN 60529) |
| Ambient operating temperature: | -25 °C ... +55 °C |
| Storage temperature: | -25 °C ... +70 °C |
| Air humidity: | 10 % ... 95 %, non-condensing |
| Vibration resistance: | (EN 60068-2-6) |