| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
|---|
| Category: | Category 4 (EN ISO 13849) |
|---|
| Performance level: | PL e (EN ISO 13849) |
|---|
| B10d parameter: | 1.26 * 1E 06 switching cycles (AC-15, 230 V, I = 1.5 A) 5.9*1E 06 switching cycles (AC-15, 230 V, I = 0.75 A) 4.35*1E 05 switching cycles (DC-13, 24 V, I = 2.5 A) 1*1E 07 switching cycles (DC-13, 24 V, I = 0.63 A) |
|---|
| PFHd: | 3.0 * 1E-08 |
|---|
| TM (mission time): | 20 a |
|---|
| Stop category: | 0, EN 60204 |
|---|
| Width: | 22.5 mm |
|---|
| Contact type: | Positively driven |
|---|
| Number of enable current contacts: | 2 |
|---|
| Number of signalling current contacts: | 1 |
|---|
| Operating voltage AC: | 24 V AC |
|---|
| Operating voltage DC: | 24 V DC |
|---|
| Maximum power consumption AC: | 4.6 VA |
|---|
| Maximum power consumption DC: | 2.1 W |
|---|
| Type of output: | Relay contacts |
|---|
| Rated operating current (voltage): | 4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h |
|---|
| Maximum switching current: | 6 A |
|---|
| Maximum total current: | 12 A |
|---|
| Mechanical life (relay contacts): | 1*1E 07 switching cycles |
|---|
| Electrical life (relay contacts): | 2* 1E 06 switching cycles, dependent upon loading, details see operating instructions |
|---|
| Enclosure rating: | IP 20 |
|---|
| Ambient operating temperature from ... to: | -25 °C ... 55 °C |
|---|
| Connection type: | Plug-in screw-type terminals |
|---|