Поставляем IN3000 Direct Sensor - IN30-E0407K - 6034582 для промышленных и гражданских объектов. Оригинальная продукция с гарантией. Подбор аналога, доставка по Москве, СПб и регионам РФ.
| Sensor principle: | Inductive |
|---|---|
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
| Category: | Applicable up to category 3 (EN ISO 13849) |
| Performance level: | PL d (EN ISO 13849) |
| PFHd: | 1.0 * 1E-07 |
| TM (mission time): | 10 a (EN ISO 13849) 20 a (EN ISO 13849) 1) |
| Housing material: | V4A (housing), PBT (cover) |
| Enclosure rating: | IP 65 (IEC 60529) IP 67 |
| Protection class: | III (EN 50178) |
| Ambient operating temperature: | -25 °C ... +70 °C |
| Electrical connection: | Plug connector, M12, 4-pin |
| Type of output: | Semiconductor |
| Number of outputs: | 2 |
| Safe switch on distance Sao: | 4 mm |
| Design: | Cylindrical |
| Dimensions: | M12 x 70 mm |
| Installation type: | Non-flush |
| Weight: | 0.08 kg |
| footnote | 1) 10 years (EN ISO 13849) at -25 °C ... +70 °C and 5 % ... 95 % relative air humidity. 20 years (EN ISO 13849) at +10 °C ... +40 °C and 5 % ... 70 % relative air humidity |