Features

Design:Cylindrical
Thread size:M12 x 1
Sensing range Sn:2 mm
Assured sensing range Sa:1.62 mm
Installation type:Flush
Switching frequency:1,200 Hz
Output type:NAMUR
Output function:NC
Enclosure rating:IP 67 1)
Electrical connection:Cable, 2-wire, 2 m
footnote1) According to EN 60529

Mechanics/electronics

Supply voltage:7.5 V DC ... 25 V DC 1)
Power consumption:? 30 mA 2)
Current consumption, sensor is activated:? 1 mA
Current consumption, sensor is not activated:? 2.2 mA
Hysteresis:1 % ... 15 %
Temperature drift (of Sr):± 10 %
EMC:According to EN 60947-5-6
Cable material:PVC
Conductor cross-section:0.34 mm?
Cable diameter:4.9 mm
Shock and vibration resistance:30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient temperature operation:-20 °C ... +70 °C
Housing cap material:Plastic, PBT
Housing length:30 mm
Thread length:29 mm
Tightening torque, max.:7 Nm
Items supplied:Fastening nuts (2 x); width across 17, metal
EC Approval Certificate:PTB 03 ATEX 2037
Hazardous area category:1G, 2G
Input voltage Ui max.:15 V 3)
Input power Pi max.:120 mW 4)
Input current Ii max.:50 mA 5)
Internal capacitance Ci max.:140 nF 6)
Internal inductance Li max.:340 µH 7)
Nominal voltage:8.2 V DC
ATEX marking:II 1 G Ex ia IIB T6 Ta: -20 °C ... +70 °C, II 2 G Ex ia IIC T6 Ta: -20 °C ... +70 °C
Cable resistance:50 ?
Housing material:Metal, Nickel-plated brass
Weight:130 g
footnote1) 2) When used outside the hazardous area 3) 4) 5) 6) 7) For connection only to a separately certified, intrinsically safe electrical circuit

Reduction factors

Note:The values are reference values which may vary
Stainless steel (V2A, 304):Ca. 0.7
Copper (Cu):Ca. 0.3
Aluminum (Al):Ca. 0.4
Brass (Br):Ca. 0.5

Installation note

B:12 mm
C:12 mm
D:6 mm
F:16 mm
Remark:Associated graphic see 'Installation'