Cylindrical threaded housing, IM12 NAMUR - IM12-04N-N-ZW0 - 6021125
Артикул: sick155444
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Design: | Cylindrical |
---|
Thread size: | M12 x 1 |
---|
Sensing range Sn: | 4 mm |
---|
Assured sensing range Sa: | 3.24 mm |
---|
Installation type: | Non-flush |
---|
Switching frequency: | 1,500 Hz |
---|
Output type: | NAMUR |
---|
Output function: | NC |
---|
Enclosure rating: | IP 67 1) |
---|
Electrical connection: | Cable, 2-wire, 2 m |
---|
footnote | 1) According to EN 60529 |
---|
Mechanics/electronics
Supply voltage: | 7.5 V DC ... 25 V DC 1) |
---|
Power consumption: | ? 30 mA 2) |
---|
Current consumption, sensor is activated: | ? 1 mA |
---|
Current consumption, sensor is not activated: | ? 2.2 mA |
---|
Hysteresis: | 1 % ... 15 % |
---|
Temperature drift (of Sr): | ± 10 % |
---|
EMC: | According to EN 60947-5-6 |
---|
Cable material: | PVC |
---|
Conductor cross-section: | 0.34 mm? |
---|
Cable diameter: | 4.9 mm |
---|
Shock and vibration resistance: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
---|
Ambient temperature operation: | -20 °C ... +70 °C |
---|
Housing cap material: | Plastic, PBT |
---|
Housing length: | 30 mm |
---|
Thread length: | 25 mm |
---|
Tightening torque, max.: | 7 Nm |
---|
Items supplied: | Fastening nuts (2 x); width across 17, metal |
---|
EC Approval Certificate: | PTB 03 ATEX 2037 |
---|
Hazardous area category: | 1G, 2G |
---|
Input voltage Ui max.: | 15 V 3) |
---|
Input power Pi max.: | 120 mW 4) |
---|
Input current Ii max.: | 50 mA 5) |
---|
Internal capacitance Ci max.: | 140 nF 6) |
---|
Internal inductance Li max.: | 130 µH 7) |
---|
Nominal voltage: | 8.2 V DC |
---|
ATEX marking: | II 1 G Ex ia IIB T6 Ta: -20 °C ... +70 °C, II 2 G Ex ia IIC T6 Ta: -20 °C ... +70 °C |
---|
Cable resistance: | 50 ? |
---|
Housing material: | Metal, Nickel-plated brass |
---|
Weight: | 127 g |
---|
footnote | 1) 2) When used outside the hazardous area 3) 4) 5) 6) 7) For connection only to a separately certified, intrinsically safe electrical circuit |
---|
Reduction factors
Note: | The values are reference values which may vary |
---|
Stainless steel (V2A, 304): | Ca. 0.7 |
---|
Copper (Cu): | Ca. 0.3 |
---|
Aluminum (Al): | Ca. 0.4 |
---|
Brass (Br): | Ca. 0.5 |
---|
Installation note
A: | 12 mm |
---|
B: | 24 mm |
---|
C: | 12 mm |
---|
D: | 12 mm |
---|
E: | 8 mm |
---|
F: | 32 mm |
---|
Remark: | Associated graphic see 'Installation' |
---|