Features
Design:
Cylindrical
Thread size:
M30 x 1.5
Sensing range Sn:
40 mm
Assured sensing range Sa:
32.4 mm
Installation type:
Non-flush
Output function:
Analog
Repeatability (Ta not constant):
0.6 mm 1) 2) 3)
Repeatability (Ta constant):
± 0.1 mm
Resolution:
? 10 µm
Enclosure rating:
IP 67 4)
Electrical connection:
Connector M12, 4-pin 5)
footnote
1) As per IEC 60947-5-2 2) Ub = DC 20 V ... 30 V 3) TA = 23 °C ± 5 °C 4) As per EN 60529: 2000-09 5) Max. cable length 300 m
Mechanics/electronics
Supply voltage:
15 V DC ... 30 V DC
Residual ripple:
? 20 % 1)
Time delay before availability:
? 50 ms
Temperature drift (of Sr):
? 10 %
Current consumption, no load:
? 12 mA 2)
Output current:
± 10 mA 3)
Load resistance, max.:
1,000 ?, 400 ? 4) 5)
Output voltage:
0 V ... 10 V
Output voltage QA1:
S = 0 mm: 0 V/-0 +0,4 V (23 °C), S = 20 mm: +5,2 V/ +-0,4 V (23 °C), S = 40 mm: +10 V/ +-0,4 V (23 °C)
Output current QA2:
S = 0 mm: 4 mA/ +-0,8 mA (23 °C), S = 40 mm: 20 mA/ +-0,8 mA (23 °C)
Bandwidth:
100 Hz 6)
Ambient temperature operation:
-25 °C ... 70 °C 7) 8)
Housing material:
Metal, Nickel-plated brass
Housing cap material:
Plastic, PBTP
Housing length:
48.5 mm
Thread length:
25 mm
footnote
1) Of VS 2) Without load 3) At voltage output QA1 4) Ub = 15 V 5) Ub = 30 V 6) -3 dB if s = 20 mm 7) QA1 loaded, QA2 unloaded 8) QA1 loaded, QA2 loaded: see temperature reduction
Reduction factors
Note:
The values are reference values which may vary
Stainless steel (V2A, 304):
Ca. 0.8
Copper (Cu):
Ca. 0.4
Aluminum (Al):
Ca. 0.4
Brass (Br):
Ca. 0.5
Installation note
A:
40 mm
B:
120 mm
C:
30 mm
D:
120 mm
E:
Aluminium: 25 mm, Stainless steal: 20 mm, Brass: 25 mm, Steel: 35 mm