Cylindrical threaded housing, MM12 NAMUR - MM12-90A-N-ZUD - 1046761
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Thread size: | M12 x 1 |
---|---|
Design: | Cylindrical |
Sensing range Sn: | 90 mm 1) |
Assured sensing range Sa: | 72.9 mm |
Magnetic sensitivity: | 0.6 mT |
Switching frequency: | 5,000 Hz |
Output type: | NAMUR |
Electrical wiring: | NAMUR |
Enclosure rating: | IP 67 2) |
Magnetic alignment: | Axial |
Connection type: | Cable, 4-wire, 0.8 m |
Output characteristic: | Control courrent depending on switching state according to NAMUR EN 60947-5-6 |
footnote | 1) Sensing range based on installation in non-magnetic material using Magnet MAG-3010-B (M4.0) 2) According to EN 60529 |
Mechanics/electronics
Housing length: | 50 mm |
---|---|
Ripple: | ? 5 % 1) |
Hysteresis: | 1 % ... 10 % |
Repeatability: | ? 1 % 2) |
Temperature drift (of Sr): | ± 10 % |
EMC: | According to EN 60947-5-2 |
Tightening torque, max.: | ? 7 Nm |
Housing material: | Metal, Nickel-plated brass |
Time delay before availability: | ? 2 ms |
Ambient operating temperature: | -25 °C ... 75 °C |
Shock and vibration resistance: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Current consumption, sensor is activated: | ? 2.5 mA |
Current consumption, sensor is not activated: | ? 1 mA |
Cable resistance: | ? 50 ? |
EC Approval Certificate: | TUV 99 ATEX 1398 |
ATEX marking: | EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C |
Hazardous area category: | 2G |
Input voltage Ui max.: | 16 V 3) |
Input power Pi max.: | 100 mW 4) |
Input current Ii max.: | 30 mA 5) |
Internal capacitance Ci max.: | 15 nF 6) |
Internal inductance Li max.: | 35 µH 7) |
Nominal voltage: | 8.2 V DC |
Wire-break protection: | 1 |
Items supplied: | Fastening nuts (2 x) |