Features

Thread size:M18 x 1
Design:Cylindrical
Sensing range Sn:70 mm 1)
Assured sensing range Sa:56.7 mm
Magnetic sensitivity:0.7 mT
Switching frequency:5,000 Hz
Output type:NAMUR
Electrical wiring:NAMUR
Enclosure rating:IP 67 2)
Magnetic alignment:Axial
Electrical connection:Cable, 2-wire, 2 m 3)
Output characteristic:Control courrent depending on switching state according to NAMUR EN 60947-5-6
footnote1) Sensing range based on installation in non-magnetic material using Magnet MAG-3010-B (M4.0) 2) According to EN 60529 3) Do not bend below 0 °C

Mechanics/electronics

Housing length:50 mm
Residual ripple:? 5 % 1)
Hysteresis:1 % ... 10 %
Repeatability:? 1 % 2)
Temperature drift (of Sr):± 10 %
EMC:According to EN 60947-5-2
Tightening torque, max.:? 25 Nm
Housing material:Metal, Nickel-plated brass
Time delay before availability:? 2 ms
Ambient temperature operation:-25 °C ... 75 °C
Shock and vibration resistance:30 g, 11 ms / 10 ... 55 Hz, 1 mm
Cable material:PVC
Current consumption, sensor is activated:? 2.5 mA
Current consumption, sensor is not activated:? 1 mA
Cable resistance:? 50 ?
EC Approval Certificate:TUV 99 ATEX 1398
ATEX marking:EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C
Hazardous area category:2G
Input voltage Ui max.:16 V 3)
Input power Pi max.:100 mW 4)
Input current Ii max.:30 mA 5)
Internal capacitance Ci max.:15 nF 6)
Internal inductance Li max.:35 µH 7)
Nominal voltage:8.2 V DC
Conductor cross-section:0.34 mm?
Wire-break protection:1
Items supplied:Fastening nuts (2 x)
footnote1) Of VS 2) Von Sr (VS und Ta constant) 3) 4) 5) 6) 7) For connection to a sperately certified intrinsically safe circuit only