Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Performance
Resolution:
0.1 mm, 1 mm
Repeatability 1):
0.15 mm
Response time 2):
10 ms
Light source:
LED, red
Measurement range 3):
0 m ... 10,000 m
Bar code width:
30 mm
Sensing distance:
100 mm, ± 20 mm
Max. movement speed:
10 m/s
Output time:
1 ms
footnote
1) Statistical error 3 ? 2) Response time of switching output 3) Dependant on the set resolution and transfer protocol
Interfaces
Data interface:
SSI
Output type 1):
MF1: PNP MF1: NPN
footnote
1) Functions of switching output MF1 PNP/MF1 NPN: position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [prefailure (dirt/LED life time), no bar code tape, over/under temperature, out of range 0 km > position > 10 km, internal error]
Mechanics/electronics
Output current IA 1):
100 mA
Supply voltage Vs 2):
DC 18 V ... 30 V
Ripple 3):
? 5 Vpp
Power consumption:
< 3 W
Initialization time:
< 3 s
Housing material:
Magnesium zinc
Weight:
Ca. 168 g
footnote
1) Switching outputs MF1 short-circuit protected 2) Limit values, reverse-polarity protected 3) May not exceed or fall below Uv tolerances
Ambient data
Enclosure rating:
IP 65 (EN 60 529)
Protection class:
III
Ambient temperature 1) 2):
Operation: -30 ... +60 °C, Storage: -40 ... +75 °C
Vibration resistance:
DIN/EN 60068-2-6, DIN/EN 60068-2-64
Shock resistance:
DIN/EN 60068-2-27
Electromagnetic compatibility (EMC):
EN 61000-6-2 / EN 61000-6-4
Typ. ambient light safety:
? 30,000 lx 3)
footnote
1) Temperatures < -20 °C with 5 min warm up time 2) Max. 95 % humidity, non-condensing 3) Typ. value at +25 °C ambient temperature