+7 (812) 200-96-95

OLM200 - OLM200-1008 - 1058813

Производитель:  Sick
Артикул: sick149673
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Resolution:0.1 mm, 1 mm, 10 mm, 100 mm
Repeatability 1):0.15 mm
Response time 2):10 ms
Light source:LED, red
Measurement range 3):0 m ... 10,000 m
Bar code width:30 mm
Sensing distance:100 mm, ± 20 mm
Max. movement speed:10 m/s
Accuracy of speed output:± 5 mm/s
Output time:2.5 ms
footnote1) Statistical error 3 ?, no warm-up time required 2) Response time of switching output 3) Dependant on the set resolution and transfer protocol

Interfaces

Data interface:EtherNet/IP 1)
Output type 2):Multifunctional output MF1: PNP Multifunctional output MF1: NPN
Data transmission rate:100 Mbit/s
Switching input:Multifunctional input MF2
footnote1) Industrial level mit Device Level Ring (DLR) 2) Functions of switching output MF1 PNP/MF1 NPN: position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [prefailure (dirt/LED life time), no bar code tape, over/under temperature, out of range 0 km > position > 10 km, internal error]

Mechanics/electronics

Output current IA 1):? 100 mA
Supply voltage Vs 2):DC 18 V ... 30 V
Ripple 3):? 5 Vpp
Power consumption:< 5.5 W
Initialization time:10 s
Housing material:Magnesium zinc
Weight:Ca. 291 g
footnote1) Switching outputs MF1 short-circuit protected 2) Limit values, reverse-polarity protected 3) May not exceed or fall below Uv tolerances

Ambient data

Enclosure rating:IP 65 (EN 60 529)
Protection class:III
Ambient temperature 1) 2):Operation: -30 ... +60 °C, Storage: -40 ... +75 °C
Vibration resistance:DIN/EN 60068-2-6, DIN/EN 60068-2-64
Shock resistance:DIN/EN 60068-2-27
Electromagnetic compatibility (EMC):EN 61000-6-2 / EN 61000-6-4 3)
Typ. ambient light safety:? 30,000 lx 4)
footnote1) Temperatures < -20 °C with 5 min warm up time 2) Max. 95 % humidity, non-condensing 3) This is a Class A device. This device can cause radio interference in living quarters. 4) Typ. value at +25 °C ambient temperature