Performance
Measurement range:
0.15 m ... 220 m, On reflective tape 'Diamond Grade'
Resolution:
0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Repeatability 1):
2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms)
Accuracy 2):
± 5 mm
Light source 3):
Laser, red
Typ. light spot size (distance):
5 mm (+ 2 mm x distance in m)
Internal measurement cycle:
1 ms
Max. movement speed:
30 m/s
Laser class:
2 (EN 60825-1 / CDRH)
Output time:
Synchronous to PLC request (dependent on interfaces)
footnote
1) Statistical error 1 ?, environmental conditions constant, depending on operating mode 2) From 150 mm ... 180 mm measuring range the accuracy can reach ± 4 mm 3) Average service life of 100,000 h at TA = +25 °C
Interfaces
Data interface:
CANopen
Output type 1):
B (push/pull) MF1, MF2
Multifunctional input (MF) 2):
1 x MF1
footnote
1) HIGH > VS - 3 V / LOW < 2 V 2) HIGH > 12 V / LOW < 3 V
Mechanics/electronics
Supply voltage Vs:
DC 18 V ... 30 V, limit values
Ripple 1):
5 Vpp
Initialization time 2):
Typ. 1.5 s
Indication:
6 digit 5 x 7 dot matrix display, LEDs
Weight 3):
Ca. 800 g ... 1,600 g
Output current IA 4):
? 100 mA
Power consumption:
At 24 V DC < 1,000 mA
Connection type:
Male connector, M12, SPEEDCON™ compatible
Housing material:
Aluminum/zinc die-cast
Modulation frequency:
Fix
footnote
1) May not fall short of or exceed VS tolerances 2) After loss of reflector < 40 ms 3) Without mounting bracket: approx. 800 g, with mounting bracket: approx. 1,600 g 4) Short circuit/overload protected. Max. 100 nF / 20 mH
Ambient data
Enclosure rating:
IP 65
Protection class:
III
Effect of air pressure:
0.3 ppm/hPa
Effect of air temperature:
1 ppm/K
Temperature drift:
Typ. 0.1 mm/K
Ambient temperature 1):
Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C
Mechanical load:
Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6
Electromagnetic compatibility (EMC) 2):
EN 61000-6-2 / EN 61000-6-4
footnote
1) Temperatures < -10 °C require warm-up time of typ. 7 minutes. 2) This is a Class A device. This device can cause radio interference in living quarters.