Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Performance
Measurement range 1):
0.15 m ... 70 m, on reflective tape 'Diamond Grade'
Resolution:
0.05 mm ... 5 mm
Repeatability 2) 3):
0.5 mm
Accuracy:
± 2 mm
Light source 4):
Laser, red
Typ. light spot size (distance):
130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m)
Output rate:
1 ms
Note:
With special frequency F1 for parallel mounting
Max. movement speed:
10 m/s
Laser class:
2 (EN 60825-1 / CDRH)
footnote
1) 2) On reflective tape 'Diamond Grade' 3) Statistical error 1 ?, environmental conditions constant, min. warm-up time 10 min 4) Average service life of 50,000 h at TA = +25 °C
Interfaces
Data interface:
SSI
Output type 1):
Push-pull: PNP/NPN (100 mA)
Multifunctional input (MF) 2) 3):
1 x MF
footnote
1) HIGH = > VS - 3 V / LOW = < 2 V 2) HIGH = > 12 V / LOW = < 3 V 3) Not reverse-polarity protected
Mechanics/electronics
Supply voltage Vs:
DC 18 V ... 30 V, limit values
Ripple 1):
< 5 Vpp
Initialization time 2):
1.5 s
Indication:
Display
Weight:
Ca. 1,650 g
Output current IA 3):
? 100 mA
Power consumption:
At 24 V DC < 250 mA
Connection type:
Male connector, M16, 8-pin
footnote
1) May not fall short of or exceed VS tolerances 2) After loss of reflector < 1 s at max. speed Vmax < 1 m/s 3) Short circuit/overload protected. Max. 100 nF / 20 mH
Ambient data
Enclosure rating:
IP 65
Protection class 1):
II
Effect of air pressure:
0.3 ppm/hPa
Effect of air temperature:
1 ppm/K
Temperature drift:
Typ. 0.1 mm/K
Ambient temperature:
Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C
Mechanical load:
Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6