+7 (812) 200-96-95

DML, DML40-2 - DML40-2-1111 - 1027607

Производитель:  Sick
Артикул: sick143263
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measurement range 1) 2) 3):0.5 m ... 1,200 m, on reflector OP60 0.5 m ... 600 m, on reflective tape 'Diamond Grade' 0.5 m ... 800 m, on reflector PL880FS01
Resolution:? 1 mm
Repeatability 4) 5):6 mm
Accuracy 6) 7):± 10 mm
Light source:Laser, infrared
Typ. light spot size (distance):20 mm (+ 5 x distance in m)
Average depth:1/16/64/256/1,024
Response time 8):1 ms ... 600 ms
Cycle time:5,120 per sec.
Laser class:1 (EN 60825-1:Nov.2001, IEC 60825-1:AM2:2001)
Output time:1 ms ... 600 ms 9)
footnote1) On reflective tape 'Diamond Grade' 2) On reflector PL880FS01 3) On reflector OP60 4) 6 % ... 90 % remission 5) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 ? 6) 23 °C air temperature, 977 hPa, min. warm-up time 30 min. 7) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5 8) 9) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format

Interfaces

Data interface 1):RS-422 RS-232
Output type 2):Q1, Q2
Interface for parametrization:RS-232
Analog output:4 mA ... 20 mA, scalable 3)
footnote1) Switchable 2) 3) Output Q short-circuit protected

Mechanics/electronics

Supply voltage Vs:DC 18 V ... 30 V, limit values
Ripple 1):5 Vpp
Initialization time:6 s
Weight:Ca. 1,200 g
Output current Ia:100 mA
Power consumption 2):? 6 W
Connection type:1 x cable gland, 1 x Sub-D, 9-pin
footnote1) May not fall short of or exceed VS tolerances 2) Without load

Ambient data

Enclosure rating:IP 65
Protection class 1):III
Temperature drift 2) 3):Typ. 0.3 mm/K Typ. 0.6 mm/K
Ambient temperature:Operation with cooling case: -10 ... +75 °C Operation: -10 ... +55 °C Storage: -25 ... +70 °C
Mechanical load:Shock: IEC 60068-2-27, -2-29 Sine: IEC 60068-2-6
Electromagnetic compatibility (EMC):EN 55011:1998 Kl. B, Gr.1 / EN 6100-6-2:1999
footnote1) Reference voltage DC 50 V PELV-voltage (EN 50178) 2) -10° C ... 0° C, +40 °C … +55 °C 3) 0 °C ... +40 °C