+7 (812) 200-96-95

DMT, DMT10-2 - DMT10-2-1211 - 1027604

Производитель:  Sick
Артикул: sick143260
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measurement range:0.5 m ... 155 m, 90 % remision 0.5 m ... 40 m, 6 % remission 0.5 m ... 65 m, 18 % remission
Resolution:? 1 mm
Repeatability 1) 2) 3) 4):10 mm, 7 mm
Accuracy 5) 6):± 10 mm
Light source:Laser, infrared
Typ. light spot size (distance):20 mm (+ 5 x distance in m)
Average depth:1/16/64/256/1,024
Aperture delay time:1 s 7)
Note:Mechanical aperture
Response time 8):1 ms ... 4,000 ms
Cycle time:1,024 per sec.
Special characteristic:Mechanical aperture
Laser class:1 (EN 60825-1:Nov.2001, IEC 60825-1:AM2:2001)
Output time:1 ms ... 4,000 ms
footnote1) Dependant on distance and remission, 7 mm, at 6 % ... 90 % remission from 0.5 m ... 65 m, at 6 % ... 18 % remission from 0.5 m ... 40 m, at 6 % remission from 0.5 m ... 15 m 2) 4) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 ? 3) Dependant on distance and remission, 10 mm, at 6 % ... 90 % remission from 60 m ... 155 m, at 6 % ... 18 % remission from 40 m ... 65 m, at 6 % remission from 15 m ... 40 m 5) 23 °C air temperature, 977 hPa, min. warm-up time 30 min. 6) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5 7) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format 8) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture Dependant on average setting, average depth, timeout, baud rate, data outpu and output format

Interfaces

Data interface:PROFIBUS DP
Output type 1):Q1, Q2
Interface for parametrization:RS-232
Analog output:4 mA ... 20 mA, scalable
footnote1) Output Q short-circuit protected

Mechanics/electronics

Supply voltage Vs:DC 18 V ... 30 V, limit values
Ripple 1):< 5 Vpp
Initialization time:6 s
Weight:Ca. 1,200 g
Output current Ia:100 mA
Power consumption 2):? 6 W
Connection type:1 x cable gland, 1 x Sub-D, 9-pin
footnote1) May not fall short of or exceed VS tolerances 2) Without load

Ambient data

Enclosure rating:IP 65
Protection class 1):III
Temperature drift 2) 3):Typ. 0.3 mm/K Typ. 0.6 mm/K
Ambient temperature:Operation with cooling case: -10 ... +75 °C Operation: -10 ... +55 °C Storage: -25 ... +70 °C
Mechanical load:Shock: IEC 60068-2-27, -2-29 Sine: IEC 60068-2-6
Electromagnetic compatibility (EMC):EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
footnote1) Reference voltage DC 50 V PELV-voltage (EN 50178) 2) -10° C ... 0° C, +40 °C … +55 °C 3) 0 °C ... +40 °C