Dx500, DS500 - DS500-N411 - 1040482
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Performance
Measurement range 1): | 0.2 m ... 7 m, 6 % ... 90 % remission |
---|---|
Resolution: | ? 1 mm |
Accuracy: | ± 3 mm |
Light source 2): | Laser, red |
Typ. light spot size (distance): | 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) |
Response time: | 150 ms |
Laser class: | 2 (EN 60825/21 CFR 1.040) |
footnote | 1) Unique up to 7 m 2) Average service life of 50,000 h at TA = +25 °C |
Interfaces
Output type 1): | NPN (< 100 mA) |
---|---|
Hysteresis: | ± 6 % |
Multifunctional input (MF) 2) 3): | < 2 V |
footnote | 1) PNP: HIGH = VS - (< 2.5 V) / LOW = < 2.5 V; NPN: HIGH = < 2.5 V / LOW = VS 2) Refer to function MF input 3) NPN < 2 V; PNP > 2 V < VS |
Mechanics/electronics
Supply voltage Vs: | DC 10 V ... 30 V, reverse polarity protected, Us ? DC 24 V for devices with heating |
---|---|
Ripple 1): | 5 Vpp |
Initialization time: | 500 ms |
Weight: | 1,000 g |
Power consumption: | Typ. 22 W |
Connection type: | Male connector, M12, 5-pin |
footnote | 1) May not fall short of or exceed VS tolerances |
Ambient data
Enclosure rating: | IP 65 |
---|---|
Protection class 1): | II |
Temperature drift: | Typ. 0.05 mm/K |
Ambient temperature: | Storage: -25 ... +75 °C Operation with heating: -40 ... +50 °C Operation with cooling case: -40 ... +75 °C |
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
Electromagnetic compatibility (EMC): | EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 |
footnote | 1) Reference voltage DC 32 V |