Features
System part:
Sensor head
Performance
Measuring range:
25 mm ... 35 mm, 6 % ... 90 % remission
Resolution 1):
1 µm
Repeatability 2):
3 µm
Linearity 3):
± 10 µm
Response time 4):
0.5 ms
Measuring frequency:
10 kHz
Light source:
Laser, red
Typ. light spot size (distance):
30 µm x 100 µm (30 mm)
Note:
Requires AOD-x
Laser class:
2 (EN 60825-1) 5)
footnote
1) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror; averaging set to: 256 2) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror; averaging set to: 256; constant ambient conditions 3) Measurement on 90 % remission (ceramic, white), for OD5-25x measurement on mirror 4) Automatic sensitivity adjustment ? 2 ms 5) Wavelength: 650 nm, max. output: 1 mW
Mechanics/electronics
Electrical connection 1) 2):
0.5 m cable with connector
Warm-up time:
? 5 min
Indication:
LEDs, 1.4'' color-display on controller unit
Weight 3):
250 g
Housing material:
Aluminum housing with glass lens
footnote
1) Extendable by cable to max. 10 m 2) Sensor must be connected to controller unit 3) Inclusive 0.5 m cable
Ambient data
Enclosure rating:
IP 67
Protection class:
III
Ambient temperature:
Operation: -10 ... 45 °C, Storage: -20 ... 60 °C
Temperature drift:
± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)