Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
System part:
Sensor head
Performance
Measuring range:
110 mm ... 190 mm, 6 % ... 90 % remission; at default settings
Resolution 1):
2 µm
Repeatability 2):
6 µm
Linearity 3):
± 40 µm
Response time 4) 5):
0.1 ms
Measuring frequency:
10 kHz 6)
Light source:
Laser, red
Typ. light spot size (distance):
0.33 mm x 1.6 mm (150 mm)
Note:
OD Precision sensor head is compatible with AOD5 hardware version 1.7. and software version 4.3 (correspond with production date from Lot 1338)
Laser class:
2 (EN 60825-1) 7)
Output time:
0.1 ms
footnote
1) 3) Measurement on 90 % remission (ceramic, white), for OD5-25x measurement on mirror; averaging set to: 4096 2) Measurement on 90 % remission (ceramic, white), for OD5-25x measurement on mirror; averaging set to: 4096; constant ambient conditions 4) Time needed for automatic sensitivity adjustment is calculated as: sampling period x 20. At default setting 100 µs (10kHz) this is
Interfaces
Data interface:
RS-422
Laser off input:
1 x laser-off
Mechanics/electronics
Electrical connection 1):
0.5 m cable with connector
Supply voltage Vs 2):
DC 12 V ... 24 V
Warm-up time:
? 5 min
Indication:
LEDs, 4'' color-display on optional controller unit
Weight 3):
250 g
Housing material:
Aluminum housing with glass lens
footnote
1) Extenable by cable to max. 50 m 2) DC 12 V (-5 %) ... DC 24 V (+10 %) 3) Inclusive 0.5 m cable
Ambient data
Enclosure rating:
IP 67
Protection class:
III
Ambient temperature:
Operation: -10 ... +50 °C, Storage: -20 ... +60 °C
Temperature drift:
± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)