+7 (812) 200-96-95

OD Value - OD2-N120W60I2 - 6036617

Производитель:  Sick
Артикул: sick156924
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Performance

Measuring range:60 mm ... 180 mm, 6 % ... 90 % remission
Resolution 1):30 µm
Repeatability 2) 3) 4) 5):90 µm
Linearity 6) 7) 8) 9):± 120 µm
Response time 10):1 ms / 10 ms / 35 ms
Measuring frequency:2 kHz
Light source:Laser, red
Typ. light spot size (distance):1 mm x 1.5 mm (120 mm)
Additional function:Automatic sensitivity adjustment, Teach-in of analog outputs, Teach-in of switching output, Invertable analog output, Invertable switching output, Averaging 1 ... 64x, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd)
Laser class:2 (EN 60825-1) 11)
footnote1) 3) 6) At averaging function medium 2) 6 % ... 90 % remission 4) Constant ambient conditions 5) 8) For best performance consider warm up time ? 5 minutes 7) Measurement on 90 % remission (ceramic, white) 9) When calibrated in the application regularly 10) Automatic sensitivity adjustment ? 4 ms, 6 ms for the models with measuring range of 100 mm ... 400 mm 11) Wavelength: 655 nm, max. output: 1 mW

Interfaces

Data interface:4 mA ... 20 mA (? 300 ?)
Output type 1):2 x NPN (100 mA)
Multifunctional input (MF) 2):1 x MF
footnote1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS 2) MF can be used as laser-off, trigger, external teach-in or deactivated; response time ? 3 ms

Mechanics/electronics

Electrical connection:Cable, 2 m
Supply voltage Vs 1):DC 12 V ... 24 V
Power consumption 2):? 2.88 W
Warm-up time:? 5 min
Indication:Distance bar graph, up to 8 status LEDs
Weight:70 g
Housing material:PBT housing with PMMA lens
footnote1) DC 12 V (-5 %) ... 24 V (+10 %); DC 18 V (-5 %) ... DC 24 V (+10 %) when using analog voltage output 2) Without load, with current output

Ambient data

Enclosure rating:IP 67
Protection class:III
Ambient temperature:Operation: -10 ... +40 °C, Storage: -20 ... +60 °C
Temperature drift:± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. ambient light safety:Artificial light: ? 3,000 lx Sunlight: ? 10,000 lx
Vibration resistance:10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance:50 G (x-, y-, z-axis 3 times each)
Relative humidity (not condensing):35 % ... 95 %