Performance
Measurement range 1):
200 mm ... 50,000 mm, on reflective tape 'Diamond Grade'
Resolution:
0.1 mm
Repeatability 2) 3) 4):
0.5 mm / 0.3 mm / 0.25 mm
Accuracy 5):
± 3 mm
Response time 6) 7):
10 ms / 40 ms / 160 ms
Light source:
Laser, red
Typ. light spot size (distance):
15 mm x 15 mm (10 m)
Additional function:
Switch-off display Unique measurement value Set moving average fast/medium/slow Set hysteresis Set parity check: none; even; odd Crosstalk safety Switching mode: distance to object (DtO) Serial data output: continuous, on request Lock user interface Reset to factory default Set data transmission rate: 19,200, 38,400, 57,600, 115,200 bps Teach-in, scaling and inversion of switching output Multifunctional in- and output: laser off, external teach, switching output 2, inactive
Laser class:
1 (EN 60825-1) 8)
Laser service life (MTTF at 25 °C):
100,000 h
Output time 9) 10):
2.5 ms
footnote
1) On reflective tape 'Diamond Grade' 2) Equivalent to 1 ? 3) 6) Dependent on the set average: fast/medium/slow 4) Typical value 5) 200 mm ... 4,000 mm: ? ± 5 mm 7) Lateral entry of object into measuring range 8) Wavelength: 658 nm; max. output: 80 mW; pulse duration: 2.5 ns; pulse repetition rate: 1/240 9) For baud rate 115,200 bps 10) Continuous change of distance in measuring range
Interfaces
Output type 1) 2) 3):
2 x / 1 x NPN (100 mA)
Hysteresis:
1 mm ... 1,000 mm
Data interface:
RS-422
Multifunctional input (MF) 4) 5) 6):
? / 1 x
footnote
1) Output Q short-circuit protected 2) NPN: HIGH = < 2.5 V / LOW = VS 3) 4) Dependent on the set function MF: switching output 2 / laser off, external teach 5) Response time ? 60 ms 6) NPN: HIGH = ? 2.5 V / LOW = VS
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A 2) May not fall short of or exceed VS tolerances 3) Without load
Ambient data
Enclosure rating:
IP 65
Protection class:
III
Ambient temperature:
Operation: -30 ... +65 °C, Storage: -40 ... +75 °C