+7 (812) 200-96-95

NT8 - NT8-02412 - 1005985

Производитель:  Sick
Артикул: sick142258
Наличие: Под заказ
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95

Features

Dimensions (L x W x H):58.8 mm x 76 mm x 30 mm
Sensing distance 1):9 mm
Sensing distance tolerance:± 2 mm
Light source 2):Incandescent lamp white
Light emission:Long and short side of housing, exchangeable
Light spot size:1.5 mm x 3.5 mm
Light spot direction 3):Vertical
Supply voltage lamp:4,5 V ± 10%
Power consumption lamp:840 mA
Adjustment:Manual adjustment, potentiometer
Function:Light/dark switching
footnote1) From front edge of lens 2) Average service life of 10,000 h at TA = + 25 °C 3) In relation to long side of housing

Mechanics/electronics

Supply voltage Vs:DC 10 V ... 30 V
Ripple:? 5 Vpp
Current consumption 1):< 50 mA
Switching frequency 2):10 kHz
Response time 3):> 50 µs
Output type:NPN: HIGH = approx. VS / LOW ? 2 V
Switching mode:NPN
Connection type:2 m cable without plug 4)
Protection class 5):II
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Enclosure rating:IP 67
Weight:Ca. 300 g
Housing material:Die-cast zinc
Output current Imax.:200 mA
footnote1) Without load 2) With light/dark ratio 1:1 3) Signal transit time with resistive load 4) Below 0 °C no deformation of cable 5) Reference voltage 50 V DC

Ambient data

Ambient temperature:Operation: 0 ... 55 °C Storage: -25 ... 85 °C
Shock load:According to IEC 60068