LUT1 - LUT1B-12205 - 1027497
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Sensing distance 1): | 80 mm |
---|---|
Operating range: | 60 mm 100 mm |
Light source 2): | LED |
Type of light: | Visible blue light |
Wave length: | 470 nm |
Light emission: | Long side |
Light spot size: | 20 mm x 50 mm |
Receiving filters: | OG 590 |
Receiving range: | 590 nm ... 750 nm |
Adjustment: | Manual ('+'/'-' button) |
Output function: | Light switching |
Dimensions (W x H x D): | 23 mm x 70 mm x 47.5 mm |
Housing design (light emission): | Rectangular |
footnote | 1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 °C |
Mechanics/electronics
Ripple 1): | < 5 Vpp |
---|---|
Power consumption 2): | < 40 mA |
Switching frequency 3): | 600 Hz |
Response time 4): | 850 µs |
Output type: | PNP: HIGH = VS- ? 2 V / LOW approx. 0 V |
Switching mode: | PNP |
Analog output QA: | 0.5 mA ... 10 mA 5) |
Output current Imax.: | 200 mA |
Connection type: | Connector M12, 5-pin |
Protection class 6): | III |
Circuit protection: | Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected |
Enclosure rating: | IP 67 |
Weight: | 240 g |
Housing material: | Metal, Zinc diecast |
Supply voltage: | 10 V DC ... 30 V DC 7) |
Fieldbus interface: | - |
footnote | 1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1, no time delay 4) Signal transit time with resistive load 5) Only LUT1B-12205 6) Reference voltage DC 50 V 7) Limit values; operation in short-circuit protected network max. 8 A |
Ambient data
Shock load: | According to IEC 60068 |
---|---|
Ambient operating temperature: | -20 °C ... +60 °C |
Ambient storage temperature: | -40 °C ... +70 °C |