WFM - WFM30-40N311 - 6037822
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Functional principle: | Optical detection principle |
---|---|
Fork width: | 30 mm |
Fork depth: | 42 mm |
Label detection: | - |
Light source: | LED |
Type of light: | Visible red light |
Adjustment: | None |
Output function: | Light switching |
Housing design (light emission): | Fork shaped |
Minimum detectable object (MDO): | 0.8 mm |
Mechanics/electronics
Residual ripple 1): | < 10 % |
---|---|
Power consumption 2): | < 20 mA |
Switching frequency 3): | 4 kHz |
Response time 4): | 125 µs |
Stability of response time: | ± 15 µs |
Output type: | NPN: HIGH = approx. VS / LOW ? 1.5 V PNP: HIGH = VS - ? 1.5 V / LOW = 0 V |
Switching mode: | NPN |
Output current Imax.: | 100 mA |
Initialization time: | 140 ms |
Electrical connection: | Connector M8, 3-pin |
Protection class 5): | III |
Circuit protection: | VS connections reverse-polarity protected Output Q short-circuit protected Interference suppression |
Enclosure rating: | IP 67 |
Weight: | Ca. 80 g ... 190 g 6) |
Housing material: | Aluminum, Metal |
Supply voltage: | 10 V DC ... 30 V DC 7) |
Ambient light immunity: | Sunlight: ? 10,000 klx |
Fieldbus interface: | - |
footnote | 1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1 4) Signal transit time with resistive load 5) Reference voltage DC 50 V 6) Depending on fork width 7) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A |
Ambient data
Shock load: | According to EN 60068-2-27 |
---|---|
UL File No.: | NRKH.E191603 NRKH7.E191603 |
Ambient temperature operation: | -10 °C ... +60 °C 1) |
Ambient storage temperature: | -40 °C ... +80 °C |
footnote | 1) Do not bend below 0 °C |